Vertiv Liebert PCW Chilled-Water Cooling: Specs and Service

The Vertiv Liebert PCW is a perimeter chilled-water cooling system for data centers, with capacities from about 11 to 220 kW per unit. It pairs an optimized coil and EC fans with iCOM controls for high efficiency and capacity per footprint, and supports high entering-water temperatures for economization. Comp-Utility, a long-standing Vertiv distribution partner, specs, installs, and services the Liebert PCW across Central Texas.

Call (512) 346-0999
Vertiv Liebert PCW Chilled-Water Cooling: Specs and Service

What We Provide

Our Capabilities

Spec and Size Cooling

We size Liebert PCW units to your heat load and integrate them with your chilled-water plant and free-cooling strategy.

Learn more

Installation and Commissioning

We install, pipe, and commission chilled-water cooling and verify capacity and tolerances under load.

Learn more

Maintenance and Service

Preventative maintenance and 24/7 response keep the PCW efficient and reliable year-round.

Learn more

High Capacity per Footprint

Chilled-Water Cooling for Larger Data Centers

The Liebert PCW delivers high cooling capacity per unit footprint, making it efficient for larger data centers that already have or plan a chilled-water plant. Its optimized coil and EC fans hold tight tolerances while keeping energy use down.

Support for higher entering-water temperatures enables economization strategies that cut mechanical cooling energy and improve PUE.

Vertiv Liebert PCW Chilled-Water Cooling: Specs and Service: Chilled-Water Cooling for Larger Data Centers

Key Specifications

AttributeVertiv Liebert PCW
TypePerimeter chilled water
Capacity11 to 220 kW per unit
AirflowUp-flow or down-flow
Key featuresOptimized coil, EC fans, high entering-water temp capability
ControlsiCOM
Typical applicationsData centers, large IT spaces

Specifications reflect the Liebert PCW product line; exact capacities and configurations vary by model. Contact us to confirm the current configuration for your project.

The Comp-Utility Difference

Why Comp-Utility?

Long-Standing Distribution Partner

As a long-standing distribution partner of Eaton, Schneider Electric, and Vertiv, we specify best-in-class systems and back them with factory-grade service.

Engineer-Owned and Operated

Comp-Utility is owned and operated by engineers, with licensed Texas Professional Engineers (P.E.) on staff. That rigor anchors every design, specification, and installation.

Turnkey, Single-Contract Partner

We sell, design, install, and maintain complete infrastructure end to end. One accountable team and one contract for power, cooling, distribution, and cabling.

24/7 Emergency Response and Preventative Maintenance

Our technicians provide preventative maintenance programs and 24/7 emergency response, with rapid on-site dispatch across Central Texas when facilities need us most.

Licensed, Certified & Recognized

We hold ourselves to the standards of the institutions we serve, from professional licensure and jobsite safety to the industry organizations that set the bar for mission-critical work.

Licensed Professional Engineers

Licensed Professional Engineers

State of Texas (TBPE)

OSHA 30 Certified

Field Technicians

AFCOM Member

AFCOM Member

Data center industry association

7x24 Exchange Member

7x24 Exchange Member

Mission-critical infrastructure

Frequently Asked Questions

What is the Vertiv Liebert PCW?

The Liebert PCW is a perimeter chilled-water precision cooling system for data centers, with capacities from about 11 to 220 kW per unit. It uses chilled water from a central plant, an optimized coil, and EC fans to deliver high efficiency and capacity per footprint while holding tight temperature and humidity tolerances.

When should I choose chilled-water over DX cooling?

Chilled-water cooling like the PCW is typically more efficient and scalable at larger capacities and is the right choice when you have or plan a central chilled-water plant. DX cooling suits smaller spaces without a chilled-water loop. Comp-Utility evaluates your size, growth, and existing infrastructure to recommend the right approach.

What is the benefit of high entering-water temperature?

Designing for higher entering-water temperatures lets the chilled-water plant use economization (free cooling) for more hours of the year, reducing mechanical cooling energy and improving PUE. The PCW supports this capability. Comp-Utility designs the system and setpoints to capture economization benefits where the climate allows.

How do I size chilled-water cooling for my data center?

Sizing is based on the IT heat load in kW, redundancy target, and growth, coordinated with the chilled-water plant capacity and flow. Comp-Utility calculates the heat load, recommends unit count and capacity for N+1 or greater redundancy, and designs the piping and airflow to deliver cooling where it is needed.

Can the PCW be deployed redundantly?

Yes. PCW units are deployed in N+1 or greater configurations so the space stays within tolerance during a unit failure or maintenance. Comp-Utility designs the cooling redundancy to match your tier and uptime goals and coordinates it with the chilled-water plant and power redundancy.

Is chilled-water cooling a good fit for Central Texas?

Yes. For larger Central Texas data centers, chilled-water systems like the PCW offer efficient, scalable cooling, and high entering-water-temperature designs can capture economization hours. Comp-Utility sizes the system for local peak conditions and designs for efficiency across the year.

Who installs and services the Liebert PCW in Central Texas?

Comp-Utility, a long-standing Vertiv distribution partner, specs, installs, commissions, and maintains the Liebert PCW across Central Texas, including preventative maintenance and 24/7 emergency response. Call (512) 346-0999 or email sales@comp-utility.com.

What maintenance does chilled-water cooling require?

Maintenance includes filter changes, coil cleaning, valve and actuator checks, EC fan inspection, condensate management, water quality and flow verification, and controls and setpoint checks. Coordinated chiller-plant maintenance is also important. Comp-Utility provides scheduled service to keep the system efficient and reliable.