Medium-Voltage Switchgear for Campus and Utility Intake

Medium-voltage (MV) switchgear and ring main units handle utility intake and distribution for large campuses and data centers, typically up to about 24kV. Platforms such as Schneider PremSet, SM6, and RM6, with EvoPacT vacuum breakers and Easergy protection relays, provide shielded, reliable MV distribution. Comp-Utility specs, installs, and services medium-voltage switchgear across Central Texas.

Call (512) 346-0999
Medium-Voltage Switchgear for Campus and Utility Intake

What We Provide

Our Capabilities

MV Switchgear Specification

We specify MV switchgear, breakers, and protection relays for utility intake and campus distribution.

Learn more

Installation and Commissioning

We coordinate installation and acceptance testing of MV switchgear with your utility and one-line.

Learn more

Testing and Maintenance

We test and maintain MV switchgear, breakers, and relays so the intake is safe and reliable.

Learn more

Utility Intake

Reliable Power at the Front Door of the Facility

Large data centers and campuses often take power at medium voltage and distribute it before stepping down. MV switchgear and ring main units provide the breakers, protection, and switching for that intake and distribution, with shielded, solid-insulation designs for reliability and safety.

Comp-Utility specifies, installs, tests, and maintains MV switchgear, coordinating protection with the rest of the electrical system.

Medium-Voltage Switchgear for Campus and Utility Intake: Reliable Power at the Front Door of the Facility

Key Specifications

AttributeMedium-Voltage Switchgear
FunctionUtility intake and campus MV distribution
VoltageUp to ~24kV
Representative productsSchneider PremSet, SM6, RM6; EvoPacT breakers; Easergy relays
TechnologyShielded solid insulation, vacuum interruption, digital protection
Typical applicationsData center MV intake, campuses, utilities

Specifications reflect representative MV switchgear platforms from our manufacturer partners; exact ratings and configurations vary. Contact us to confirm the current configuration for your project.

The Comp-Utility Difference

Why Comp-Utility?

Long-Standing Distribution Partner

As a long-standing distribution partner of Eaton, Schneider Electric, and Vertiv, we specify best-in-class systems and back them with factory-grade service.

Engineer-Owned and Operated

Comp-Utility is owned and operated by engineers, with licensed Texas Professional Engineers (P.E.) on staff. That rigor anchors every design, specification, and installation.

Turnkey, Single-Contract Partner

We sell, design, install, and maintain complete infrastructure end to end. One accountable team and one contract for power, cooling, distribution, and cabling.

24/7 Emergency Response and Preventative Maintenance

Our technicians provide preventative maintenance programs and 24/7 emergency response, with rapid on-site dispatch across Central Texas when facilities need us most.

Licensed, Certified & Recognized

We hold ourselves to the standards of the institutions we serve, from professional licensure and jobsite safety to the industry organizations that set the bar for mission-critical work.

Licensed Professional Engineers

Licensed Professional Engineers

State of Texas (TBPE)

OSHA 30 Certified

Field Technicians

AFCOM Member

AFCOM Member

Data center industry association

7x24 Exchange Member

7x24 Exchange Member

Mission-critical infrastructure

Frequently Asked Questions

What is medium-voltage switchgear?

Medium-voltage switchgear is electrical equipment that switches, protects, and distributes power at medium voltage, typically up to about 24kV, often at a facility's utility intake. It includes circuit breakers or switches, protection relays, and metering. Large data centers and campuses use MV switchgear to receive and distribute utility power before transformers step it down to low voltage.

When does a facility need medium-voltage switchgear?

A facility needs MV switchgear when it takes utility power at medium voltage, which is common for large data centers and campuses with high total demand, or when distributing power across a large site at medium voltage before local step-down. Comp-Utility's engineers determine whether your load and utility service warrant MV distribution.

What is a ring main unit (RMU)?

A ring main unit is a compact medium-voltage switchgear assembly used to connect into a utility ring or loop distribution, providing switching and protection for a transformer or feeder. RMUs like the Schneider RM6 are common at the intake of larger facilities. Comp-Utility specifies and installs RMUs as part of MV intake design.

What protection do MV systems require?

MV systems require protective relays that detect faults and operate breakers to isolate them quickly, coordinated with the utility and downstream protection. Digital relays such as Schneider Easergy provide this protection and control. Comp-Utility specifies and tests protection relays and coordinates the scheme so faults are cleared safely and selectively.

How is medium-voltage switchgear maintained?

MV switchgear maintenance includes inspection, insulation and contact testing, vacuum breaker testing, protective relay testing, and thermography, performed by qualified personnel following strict safety procedures because of the voltage. Comp-Utility maintains and tests MV switchgear and documents results, coordinating any required outages carefully.

Do you coordinate MV work with the utility?

Yes. MV intake design, installation, and switching often require coordination and approval from the serving utility, including protection coordination and metering. Comp-Utility's engineers work with your utility on the intake design and requirements as part of a turnkey project, so the MV system meets utility and code requirements.

Which MV switchgear does Comp-Utility provide?

As a Schneider Electric distribution partner, Comp-Utility provides MV switchgear including Schneider PremSet, SM6, and RM6, with EvoPacT vacuum breakers and Easergy protection relays, among others. We specify, install, test, and maintain MV systems across Central Texas. Call (512) 346-0999 to discuss your intake.

Who installs and services MV switchgear in Central Texas?

Comp-Utility specs, installs, commissions, tests, and maintains medium-voltage switchgear across Central Texas, with licensed Texas Professional Engineers and qualified technicians, and 24/7 emergency response. Call (512) 346-0999 or email sales@comp-utility.com.